01 / ITC · MST
Binding & thermodynamics
Determine how confidently the available data support an interaction model, binding affinity and thermodynamic interpretation. Where warranted by data quality and experimental design, evaluate alternatives to a simple 1:1 interaction.
Questions we address
- What affinity and stoichiometry are supported?
- Do alternative binding models meaningfully improve the fit?
- Why might ITC and MST appear to disagree?
Data accepted
- ITC raw exports, integrated heats and metadata
- MST response curves, concentration series and instrument exports
- CSV, XLSX or native formats reviewed during scoping
Typical deliverables
- Documented fits, parameter estimates and uncertainty
- Assessment of model suitability and limitations
- Clear scientific interpretation and suggested next steps
02 / DSC · CD
Stability & structure
Interpret thermal transitions, unfolding behaviour and conformational measurements, including comparative evaluation of formulation or buffer conditions.
Questions we address
- What transitions or melting behaviour are evident?
- How do buffer or formulation conditions compare?
- What does the CD signal support regarding secondary structure?
Data accepted
- DSC thermograms and metadata
- CD spectra, temperature ramps and instrument exports
- Numerical tables and associated sample-condition notes
Typical deliverables
- Transition summaries and relevant fitted parameters
- Condition comparisons and QC observations
- Interpretation with stated assumptions and uncertainty
03 / MECHANISMS · RATE CONSTANTS
Kinetics & electrochemistry
Review time-dependent and electrochemical datasets to identify appropriate analysis strategies, evaluate kinetic parameters and investigate whether the proposed mechanism is justified.
Questions we address
- Which kinetic models are consistent with the measurements?
- How robust are estimated rate constants?
- What alternatives could explain the electrochemical response?
Data accepted
- Time-series and kinetic measurement exports
- Potential/current traces and numerical electrochemical datasets
- Instrument details, protocols and experimental context
Typical deliverables
- Fitting assessment and parameter reporting
- Mechanistic interpretation with limitations
- Recommendations for confirming experiments
04 / EXPERIMENT REVIEW · INDEPENDENT SECOND OPINIONS
Troubleshooting & consultancy
Independent review for ambiguous or noisy experiments, puzzling trends and analysis approaches that need another expert perspective.
Questions we address
- Is the issue data quality, experimental design or interpretation?
- Could baseline corrections or model selection be influencing conclusions?
- What should be repeated, controlled or measured next?
Data accepted
- Existing reports, plots, analysis outputs and suitable raw data
- Experiment and sample metadata where available
- An agreed set of questions or decisions to evaluate
Typical deliverables
- Diagnostic review and issue prioritisation
- Transparent second-opinion assessment
- Practical next-step recommendations
Scope: Valiron analyses client-supplied data. We do not perform laboratory experiments. Specific techniques, instrument exports, models and deliverables are confirmed during project scoping.